Izinhlobo ezingama-28 ze-HPV Nucleic Acid

Incazelo emfushane:

Ikhithi isetshenziselwa ukutholwa kwe-in vitro qualitative yezinhlobo ezingama-28 ze-human papillomaviruses (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53 , 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) i-nucleic acid kumchamo wesilisa/ wesifazane kanye namaseli akhishwe wesibeletho sowesifazane, kodwa igciwane alikwazi ukuthayipha ngokuphelele.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo

I-HWTS-CC003A-28 Izinhlobo ze-HPV Nucleic Acid Detection Kit (Fluorescence PCR)

Isitifiketi

CE

I-Epidemiology

Umdlavuza womlomo wesibeletho ungesinye sezimila eziyingozi ezivame kakhulu emgudwini wokuzala wabesifazane.Ucwaningo luye lwabonisa ukuthi ukutheleleka okuqhubekayo kanye nokutheleleka okuningi kwe-human papillomavirus kungenye yezimbangela ezibalulekile zomdlavuza womlomo wesibeletho.Okwamanje, kusenokuntuleka kwezindlela zokwelapha ezisebenzayo ze-HPV.Ngakho-ke, ukutholakala kusenesikhathi kanye nokuvimbela kusenesikhathi kwe-HPV yomlomo wesibeletho kuyisihluthulelo sokuvimba umdlavuza.Ukusungulwa kwendlela elula, eqondile futhi esheshayo yokuxilonga i-pathogenic kubaluleke kakhulu ekuxilongweni komtholampilo komdlavuza womlomo wesibeletho.

Isiteshi

I-S/N Isiteshi Uhlobo
I-PCR-Mix1 FAM 16, 18, 31, 56
I-VIC(HEX) Ukulawula Kwangaphakathi
CY5 45, 51, 52, 53
I-ROX 33, 35, 58, 66
I-PCR-Mix2 FAM 6, 11, 54, 83
I-VIC(HEX) 26, 44, 61, 81
CY5 40, 42, 43, 82
I-ROX 39, 59, 68, 73

Imingcele Yezobuchwepheshe

Isitoreji ≤-18℃ ebumnyameni
Impilo yeshelufu Izinyanga ezingu-12
Uhlobo lwesifanekiso Amaseli e-exfoliated womlomo wesibeletho
Ct ≤28
CV ≤5.0%
LoD 300Amakhophi/mL
Ukucaciswa Akukho ukuphinda kusebenze okunamagciwane ajwayelekile epheshana lokuzala (njenge-ureaplasma urealyticum, i-genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, isikhunta, i-gardnerella nezinye izinhlobo ze-HPV ezingafakwanga kukhithi, njll).
Izinsimbi Ezisebenzayo Ingakwazi ukufanisa amathuluzi e-PCR e-fluorescent avamile emakethe.

I-ABI 7500 Real-Time PCR Systems

I-QuantStudio® 5 Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems

Uhlelo lwe-PCR lwe-LightCycler®480 Real-Time

LineGene 9600 Plus Real-Time PCR Uhlelo Lokuthola

I-MA-6000 Real-Time Quantitative Thermal Cycler

Isixazululo se-PCR esiphelele

Inketho 1.

I-Fluorescence PCR3

Inketho yesi-2.

I-Fluorescence PCR4

  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha futhi usithumelele wona